SS 100 Specifications Print E-mail
SIMULATED CONTACTS
Main:3 x volt-free contact outputs for simulation of 1 main contact per phase.
Resistive:
3 x volt-free contact outputs for simulation of 1 resistive contact per phase.
Connectors:4mm safety socket.
  
SIMULATED COILS
Coil Operation:Volt-Free pulsed contact inputs required for open (trip) and close.
Coil Peak Current:
1.4A DC.
Coil Voltage:12V DC, fused.
Protection:Inhibit / Enable of each coil circuit to prevent continuous or simultaneous operation of coils.
Connectors:4mm safety socket.

 
SIMULATED TRAVEL / MOTION 
Type:
Slide-wire.
Mechanical Stroke:
25mm.
Connectors:
4mm safety sockets.
  
MEASUREMENTS  
Operation:
Open, Close, Trip Free, Close-Open, Open-Close, Open-Close-Open.
Digital Timing:
Main, Resistive or Main + Resistive in parallel using links provided.
Dynamic Timing:
4-wire Current Injection and Voltage Drop Sensing with option to earth both sides using links provided.
P.I.R. :
Parallel contact switching resistors at 180 ohms.
  
GENERAL SYSTEM
 Operating Time:<100mSec.
 Position Indication:Green LED = Open, Red LED = Closed.
 Power Output:12V DC, 3A max.
  
OPERATING VOLTAGES
 
Prime Power:88 to 264V AC auto-sensing via IEC power connection. Typical burden <30 VA.
  
ENVIRONMENTAL 
Operating Temp.:-20ºC to +70ºC (-4ºF to +158ºF)
Humidity:0 to 97% RH non-condensing.
Isolation:2kV rms for 1 minute (channel to channel, channel to earth).
Surge Withstand:To IEC 801-5.  1.2/50S.
(Transient)Common Mode: Severity level class 4.   Series Mode: Severity level class 3.
Fast Transient Burst:To IEC 801-4 level 3.
RFI Immunity:To IEC801-3 level 3.  10V/m 26-1000MHz.
Emissions:To EN50081-1: 1992.
  
MECHANICAL DETAILS
  
Enclosure:Reinforced aluminium, 370mm(W) x 245mm(H) x 180mm(D).
Weight:   
<3kg.
DUE TO CONTINUING DEVELOPMENT AND IMPROVEMENTS WEIS RESERVES THE RIGHT TO CHANGE THIS SPECIFICATION WITHOUT NOTICE