Weis GmbH Number ONE in Breaker Testing

you are here: Home arrow Products arrow RT100 arrow Specifications

Mittwoch, 17 März 2010
Main Menu
Home
About us
Products
Contact
Download
Distributor
Search
Newsletter
Sitemap
Who's Online
PS 100 Power Supply
Newsletter

Please subscribe the newsletter, if you want to stay informed about our new products.






RT100 Specifications RelayTester Secondary Injection Relay Test Set Print E-mail
OUTPUTS
AC Current:0 to 10A range with the following characteristics:-
 

No-Load Voltage (min.): 80V

Full-Load Voltage (min.): 70V

Full-Load Current (max.): 10A

Time: 2 hours

Safety: Output transformer equipped with built-in temperature protection.

Primary side protected by miniature circuit breakers.

0 to 25A range with the following characteristics:-

No-Load Voltage (min.): 24V

Full-Load Voltage (min.): 20V

Full-Load Current (max.): 25A

Time: 1 hour

Safety: Output transformer equipped with built-in temperature protection.

Primary side protected by miniature circuit breakers.

 

0 to 50A (short term max. 200A peak) range with the following characteristics:-

No-Load Voltage (min.): 10V

Full-Load Voltage (min.): 2V

Full-Load Current (max.): 50A

Time: 1.5 minutes

Safety: Output transformer equipped with built-in temperature protection.

Primary side protected by miniature circuit breakers.

AC/DC Voltage: 0 to 240V AC rated at 2A for 1 hour.

0 to 300V DC rated at 2A for 1 hour.

Auxiliary Voltage: 240V AC rated at 0.5A.

240V AC rated at 0.5A. 110V DC rated at 0.5A, 110V AC rated at 0.5A & 30V DC rated at 1A.

If the 110V DC & AC fixed outputs are used simultaneously the rating is 0.2A each.

Safety (Voltage): Re-triggerable fuses used in all voltage outputs

INPUTS 
Digital:2 x wet contacts and 1 x dry contact.
  
TIMER 
Range:0.000 to 999.999 seconds, auto-ranging.
Resolution:1mSec.
Max. Testing Time:999.999 seconds.
MEASUREMENTS 
Readout:

Output parameters are displayed on a large backlit LCD display.

Auto-ranging if output is less than 10% of range.

Measured Quantities:

AC current output.

Timer.

Accuracy:±0.5% of metering.
AC Measurement:True RMS.
Set of Resistors: 0.5Ω (10A max.), 1Ω (5A max.), 25Ω (2A max.), 100Ω (0.7A max.) & 500Ω (0.3A max.).
OPERATING VOLTAGES 
Prime Power:230 or 115V AC ±15%, 50/60Hz.
ENVIRONMENTAL 

Operating

Temperature:

-20ºC to +70ºC

Storage

Temperature:

-40ºC to +70ºC

MECHANICAL DETAILS  
Weight:10kg.
Carry Case:Reinforced aluminium, 13.5” x 9.5” x 6” (340mm x 240mm x 150mm).
  
DUE TO CONTINUING DEVELOPMENT AND IMPROVEMENTS WEIS RESERVES THE RIGHT TO CHANGE THIS SPECIFICATION WITHOUT NOTICE